GMI D2050M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

GMI
D2050M
Interface Multiplexer Systems
Fast Delivery
GMI D2050M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
LUMIKIZANANI NAFE

Your email address will not be published. Required fields are marked with *

kaonekeswe

DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe Associated Apparatus for installation in Safe Area/Non Hazardous Locations to supply Multiplexer D2010M, D2011M, D2030M installed in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Universal inputs (mV, TC, RTD, contact or proximity detector) via D2010M, D2011M, D2030M unit from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Expandability up to 256 analog/128 digital channels per system and 31 systems on a single Modbus serial link for up to 7936/3968 channels.

Redundant field lines for communication/supply.

Modbus interface RTU protocol on redundant RS-485.

RS-232 port for system configuration.

Three port isolation, Input/Output/Supply.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

Configurable by SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

Repeat Hazardous Area/Hazardous Locations input contact or proximity detector in Safe Area/Non Hazardous Locations via D2052M unit (relay output) or via D2053M unit (transistor output).


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Chifukwa Chosankha Ife:

1. Mutha kupeza zinthu zabwino kwambiri malinga ndi zomwe mukufuna pamtengo wotsika kwambiri.

2. Timaperekanso Reworks, FOB, CFR, CIF, ndi mitengo yobweretsera khomo ndi khomo. Tikukulangizani kuti mugwiritse ntchito zotumiza zomwe zingakhale zotsika mtengo.

3. Zipangizo zomwe timapereka ndizotsimikizika kotheratu, kuyambira pa satifiketi yoyeserera mpaka pagawo lomaliza.

4. Timatsimikizira kupereka yankho mkati mwa 24hours (nthawi zambiri mu ola lomwelo)

5. Mutha kupeza njira zina zogulitsira, zoperekera mphero ndikuchepetsa nthawi yopanga.

6. Ndife odzipereka kwathunthu kwa makasitomala athu. Ngati sizingatheke kukwaniritsa zomwe mukufuna mutapenda zonse zomwe mungasankhe, sitidzakusocheretsani popanga malonjezo abodza omwe angapangitse ubale wabwino ndi makasitomala.


Kodi chinachitika n'chiyani?

1. Kutsimikizira kwa imelo

Mudzalandira imelo yotsimikizira kuti talandira zomwe mwafunsa.

2. Exclusive Sales Manager

Mmodzi wa gulu lathu adzakulumikizani kuti atsimikizire gawo(ma)magawo anu ndi momwe zilili.

3. Mawu anu

Mudzalandira ndemanga yathunthu yogwirizana ndi zosowa zanu.


2000+ Zogulitsa Zomwe Zilipo

100% Fakitale Yatsopano Yatsopano Yosindikizidwa - Yoyambirira

Kutumiza Padziko Lonse - Othandizana nawo UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Warranty Miyezi 12 - Zigawo zonse zatsopano kapena zokonzedwanso

Palibe ndondomeko yobwezera zovuta - Gulu lothandizira makasitomala odzipereka

Malipiro - PayPal, kirediti kadi/debit card, kapena Bank/Wire Transfer

Payment


HKXYTECH siwogawa ovomerezeka kapena woimira opanga omwe ali patsamba lino. Mayina amtundu ndi zilembo zomwe zawonetsedwa ndi eni ake.

Zogulitsa Zogwirizana
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Kusaka kwazinthu