DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer Expander D2011M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2011M scans all channels using state of the art solid state isolated relays, and stores all data in the D2010M memory buffer connected to it, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2011M unit accepts directly up to 16 input channels. An integrating type, high rejection, high accuracy (18 bits) A/D converter installed on D2010M unit that control up to three Expander D2011M, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit and stored in the D2010M unit connected to the Expander.


FEATURES

Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

High reliability, SMD components.

High density, 16 channels per unit.

1 terminal block per input, no external terminal block required.


CHANNELS

16


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Chifukwa Chosankha Ife:

1. Mutha kupeza zinthu zabwino kwambiri malinga ndi zomwe mukufuna pamtengo wotsika kwambiri.

2. Timaperekanso Reworks, FOB, CFR, CIF, ndi mitengo yobweretsera khomo ndi khomo. Tikukulangizani kuti mugwiritse ntchito zotumiza zomwe zingakhale zotsika mtengo.

3. Zipangizo zomwe timapereka ndizotsimikizika kotheratu, kuyambira pa satifiketi yoyeserera mpaka pagawo lomaliza.

4. Timatsimikizira kupereka yankho mkati mwa 24hours (nthawi zambiri mu ola lomwelo)

5. Mutha kupeza njira zina zogulitsira, zoperekera mphero ndikuchepetsa nthawi yopanga.

6. Ndife odzipereka kwathunthu kwa makasitomala athu. Ngati sizingatheke kukwaniritsa zomwe mukufuna mutapenda zonse zomwe mungasankhe, sitidzakusocheretsani popanga malonjezo abodza omwe angapangitse ubale wabwino ndi makasitomala.


Kodi chinachitika n'chiyani?

1. Kutsimikizira kwa imelo

Mudzalandira imelo yotsimikizira kuti talandira zomwe mwafunsa.

2. Exclusive Sales Manager

Mmodzi wa gulu lathu adzakulumikizani kuti atsimikizire gawo(ma)magawo anu ndi momwe zilili.

3. Mawu anu

Mudzalandira ndemanga yathunthu yogwirizana ndi zosowa zanu.


2000+ Zogulitsa Zomwe Zilipo

100% Fakitale Yatsopano Yatsopano Yosindikizidwa - Yoyambirira

Kutumiza Padziko Lonse - Othandizana nawo UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Warranty Miyezi 12 - Zigawo zonse zatsopano kapena zokonzedwanso

Palibe ndondomeko yobwezera zovuta - Gulu lothandizira makasitomala odzipereka

Malipiro - PayPal, kirediti kadi/debit card, kapena Bank/Wire Transfer

Payment


HKXYTECH siwogawa ovomerezeka kapena woimira opanga omwe ali patsamba lino. Mayina amtundu ndi zilembo zomwe zawonetsedwa ndi eni ake.

Zogulitsa Zogwirizana
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Kusaka kwazinthu