GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

GMI
D2030M
Interface Multiplexer Systems
Fast Delivery
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
KPỌTỤRỤ ANYỊ

Your email address will not be published. Required fields are marked with *

nkowa

DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Inputs from voltage free contacts or EN60947-5-6 proximity detectors from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Expandability up to 128 digital channels per system and 31 systems on a single Modbus serial link for up to 3968 channels.

Redundant field lines for communication/supply.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

High density, 32 channels per unit, 128 channels per system.

Configurable via D2050M Gateway using PC SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

1 terminal block per input, no external terminal block required.


CHANNELS

32


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Ihe kpatara ịhọrọ anyị:

1. Ị nwere ike nweta ihe zuru oke dịka ihe ị chọrọ na ọ dịkarịa ala ọnụahịa.

2. Anyị na-enyekwa Reworks, FOB, CFR, CIF, na ọnụ ụzọ nnyefe ọnụ ụzọ. Anyị na-atụ aro ka ịme azụmahịa maka mbupu nke ga-adị oke ọnụ ahịa.

3. Ihe anyị na-enye bụ nkwenye kpamkpam, site na akwụkwọ nyocha nke akụrụngwa ruo na nkwupụta akụkụ ikpeazụ. (Akụkọ ga-egosi na achọrọ)

4. Anyị na-ekwe nkwa inye nzaghachi n'ime 24hours (na-emekarị n'otu awa)

5. Ị nwere ike nweta ngwaahịa ọzọ, igwe ihe nnyefe na ibelata n'ichepụta oge.

6. Anyị raara onwe anyị nye ndị ahịa anyị kpamkpam. Ọ bụrụ na ọ gaghị ekwe omume imezu ihe ndị ị chọrọ mgbe ị nyochachara nhọrọ niile, anyị agaghị eduhie gị site n'ịkwe nkwa ụgha nke ga-eme ka ndị ahịa dị mma.


Gịnị ga-eme ọzọ?

1. nkwenye email

Ị ga-enweta ozi-e na-akwado na anyị enwetala ajụjụ gị.

2. Nanị Sales Manager

Otu n'ime ndị otu anyị ga-akpọtụrụ iji kwado nkọwapụta na ọnọdụ akụkụ (s) gị.

3. Okwu gị

Ị ga-enweta ọnụ ọgụgụ zuru ezu ahaziri maka mkpa gị.


Ngwaahịa 2000+ dị n'ezie

100% Brand New Factory Akara - Nke izizi

Mbupu zuru ụwa ọnụ - ndị mmekọ Logistic UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Akwụkwọ ikike ọnwa 12 - Akụkụ niile dị ọhụrụ ma ọ bụ emezigharịrị

Enweghị amụma nloghachi nsogbu - otu nkwado ndị ahịa raara onwe ya nye

Ịkwụ Ụgwọ - PayPal, Kaadị kredit/Debit, ma ọ bụ Nyefee Bank/Waya

Payment


HKXYTECH abụghị onye nkesa ikike ma ọ bụ onye nnọchi anya ndị nrụpụta egosipụtara na webụsaịtị a. Aha ika na ụghalaahịa egosipụtara bụ ihe onwunwe nke ndị nwe ha.

Ngwaahịa metụtara
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Nchọpụta ngwaahịa