Your email address will not be published. Required fields are marked with *
DESCRIPTION
D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer Expander D2011M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2011M scans all channels using state of the art solid state isolated relays, and stores all data in the D2010M memory buffer connected to it, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2011M unit accepts directly up to 16 input channels. An integrating type, high rejection, high accuracy (18 bits) A/D converter installed on D2010M unit that control up to three Expander D2011M, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit and stored in the D2010M unit connected to the Expander.
FEATURES
Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.
Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.
Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.
EMC Compatibility to EN61000-6-2, EN61000-6-4.
High reliability, SMD components.
High density, 16 channels per unit.
1 terminal block per input, no external terminal block required.
CHANNELS
16
RELATED MODELS
D2010M
D2011M
D2030M
D2050M
D2052M
D2053M
Ihe kpatara ịhọrọ anyị:
1. Ị nwere ike nweta ihe zuru oke dịka ihe ị chọrọ na ọ dịkarịa ala ọnụahịa.
2. Anyị na-enyekwa Reworks, FOB, CFR, CIF, na ọnụ ụzọ nnyefe ọnụ ụzọ. Anyị na-atụ aro ka ịme azụmahịa maka mbupu nke ga-adị oke ọnụ ahịa.
3. Ihe anyị na-enye bụ nkwenye kpamkpam, site na akwụkwọ nyocha nke akụrụngwa ruo na nkwupụta akụkụ ikpeazụ. (Akụkọ ga-egosi na achọrọ)
4. Anyị na-ekwe nkwa inye nzaghachi n'ime 24hours (na-emekarị n'otu awa)
5. Ị nwere ike nweta ngwaahịa ọzọ, igwe ihe nnyefe na ibelata n'ichepụta oge.
6. Anyị raara onwe anyị nye ndị ahịa anyị kpamkpam. Ọ bụrụ na ọ gaghị ekwe omume imezu ihe ndị ị chọrọ mgbe ị nyochachara nhọrọ niile, anyị agaghị eduhie gị site n'ịkwe nkwa ụgha nke ga-eme ka ndị ahịa dị mma.
Gịnị ga-eme ọzọ?
1. nkwenye email
Ị ga-enweta ozi-e na-akwado na anyị enwetala ajụjụ gị.
2. Nanị Sales Manager
Otu n'ime ndị otu anyị ga-akpọtụrụ iji kwado nkọwapụta na ọnọdụ akụkụ (s) gị.
3. Okwu gị
Ị ga-enweta ọnụ ọgụgụ zuru ezu ahaziri maka mkpa gị.
Ngwaahịa 2000+ dị n'ezie
100% Brand New Factory Akara - Nke izizi
Mbupu zuru ụwa ọnụ - ndị mmekọ Logistic UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…
Akwụkwọ ikike ọnwa 12 - Akụkụ niile dị ọhụrụ ma ọ bụ emezigharịrị
Enweghị amụma nloghachi nsogbu - otu nkwado ndị ahịa raara onwe ya nye
Ịkwụ Ụgwọ - PayPal, Kaadị kredit/Debit, ma ọ bụ Nyefee Bank/Waya

HKXYTECH abụghị onye nkesa ikike ma ọ bụ onye nnọchi anya ndị nrụpụta egosipụtara na webụsaịtị a. Aha ika na ụghalaahịa egosipụtara bụ ihe onwunwe nke ndị nwe ha.
Nchọpụta ngwaahịa