DESCRIPTION

The Isolating Driver X1-IS-AO-01 module is a high integrity analog output interface suitable for applications requiring SIL 3 level in safety related systems for high risk industries. It isolates and transfers a 4-20 mA signal from a controller located in Safe Area to a load in Hazardous Area. The circuit allows bi-directional communication signals, for HART® smart positioners. Line and load open/short circuit detection is provided: the fault in the field is directly mirrored to the PLC AO card as open circuit and it is also reported on the common fault line. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES

SIL 3 / SC 3

Input from Zone 0 / Division 1

Installation in Zone 2 / Division 2

Loop disconnection to ease maintenance operations

HART® compatible

Line & Load short/open circuit programmable diagnostics

Out-of-range fault with programmable thresholds

Field fault mirroring to the DCS/PLC IO Card

High Accuracy

Three port isolation, Input/Output/Supply


CHANNELS

1


RELATED MODEL

D1022D

D1022S

D5020D

D5020S

X1-IS-AO-01-S

X1-IS-AO-02-S

D1020D

D1020S



Kungani Usikhethe:

1. Ungathola impahla ephelele ngokuvumelana nemfuneko yakho okungenani inani elingenzeka.

2. Siphinde sinikeze ama-Reworks, i-FOB, i-CFR, i-CIF, nezintengo zokudiliva umnyango nomnyango. Siphakamisa ukuthi wenze isivumelwano sokuthunyelwa okuzokonga kakhulu.

3. Izinto esizihlinzekayo zingaqinisekiswa ngokuphelele, kusukela kusitifiketi sokuhlolwa kwempahla engavuthiwe kuya esitatimendeni sobukhulu bokugcina.(Imibiko izovela ngokwemfuneko)

4. Siqinisekisa ukunikeza impendulo phakathi namahora angu-24(imvamisa ngehora elifanayo)

5. Ungathola ezinye izindlela zesitoko, ukulethwa kwezigayo ngokunciphisa isikhathi sokukhiqiza.

6. Sizinikele ngokugcwele kumakhasimende ethu. Uma kungeke kwenzeke ukuhlangabezana nezidingo zakho ngemva kokuhlola zonke izinketho, ngeke sikudukise ngokwenza izithembiso ezingamanga ezizodala ubudlelwano obuhle namakhasimende.


Kwenzekani ngokulandelayo?

1. Ukuqinisekiswa kwe-imeyili

Uzothola i-imeyili eqinisekisa ukuthi siwutholile umbuzo wakho.

2. Umphathi Wokuthengisa Okukhethekile

Omunye wethimba lethu uzoxhumana naye ukuze aqinisekise ukucaciswa kwengxenye yakho nesimo.

3. Isilinganiso sakho

Uzothola ikhotheshini ebanzi ehambisana nezidingo zakho ezithile.


2000+ Imikhiqizo Iyatholakala Ngempela

100% Imboni Entsha Yomkhiqizo Ivaliwe - Eyoqobo

Ukuthumela Ngomhlaba Wonke - Ozakwethu be-Logistic UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express...

Iwaranti Izinyanga eziyi-12 - Zonke izingxenye ezintsha noma zilungiswe kabusha

Ayikho inqubomgomo yembuyiselo yokuhlupheka - Ithimba elizinikele lokusekela amakhasimende

Inkokhelo - I-PayPal, ikhadi lesikweletu/ledebhithi, noma I-Bank/Wire Transfer

Payment


I-HKXYTECH ayiyena umsabalalisi ogunyaziwe noma omele abakhiqizi abafakwe kule webhusayithi. Amagama ebhrendi nezimpawu zokuhweba ezifakiwe ziyimpahla yabanikazi bazo.

Imikhiqizo ehlobene
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators

Ukucinga Umkhiqizo