DESCRIPTION
D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer Expander D2011M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2011M scans all channels using state of the art solid state isolated relays, and stores all data in the D2010M memory buffer connected to it, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2011M unit accepts directly up to 16 input channels. An integrating type, high rejection, high accuracy (18 bits) A/D converter installed on D2010M unit that control up to three Expander D2011M, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit and stored in the D2010M unit connected to the Expander.
FEATURES
Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.
Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.
Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.
EMC Compatibility to EN61000-6-2, EN61000-6-4.
High reliability, SMD components.
High density, 16 channels per unit.
1 terminal block per input, no external terminal block required.
CHANNELS
16
RELATED MODELS
D2010M
D2011M
D2030M
D2050M
D2052M
D2053M
為什麼選擇我們:
1.您可以根據您的要求以最低的價格獲得完美的材料。
2.我們還提供返修、FOB、CFR、CIF和門到門交貨價格。我們建議您進行運費交易,這將非常經濟。
3.我們提供的材料是完全可驗證的,從原材料測試證書到最終的尺寸聲明。(報告將根據要求顯示)
4. 我們保證在 24 小時內給予回复(通常在同一小時內)
5. 您可以獲得庫存替代品、工廠交貨,並最大限度地縮短製造時間。
6. 我們全心全意為客戶服務。如果在檢查所有選項後仍無法滿足您的要求,我們不會通過虛假承諾誤導您,從而建立良好的客戶關係。
接下來發生什麼?
1. 電子郵件確認
您將收到一封電子郵件,確認我們已收到您的詢問。
2. 專屬銷售經理
我們的一個團隊將與您聯繫以確認您的零件規格和狀況。
3. 您的報價
您將收到根據您的特定需求量身定制的綜合報價。
2000 多種產品真正可用
100% 全新工廠密封 - 原裝
全球航運 - 物流合作夥伴 UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…
保修 12 個月 - 所有部件全新或翻新
無憂退貨政策 - 專門的客戶支持團隊
付款 - 貝寶、信用卡/借記卡或銀行/電匯

HKXYTECH 不是本網站上所列製造商的授權經銷商或代表。品牌名稱和商標是其各自所有者的財產。
產品搜索