DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe Associated Apparatus for installation in Safe Area/Non Hazardous Locations to supply Multiplexer D2010M, D2011M, D2030M installed in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Universal inputs (mV, TC, RTD, contact or proximity detector) via D2010M, D2011M, D2030M unit from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Expandability up to 256 analog/128 digital channels per system and 31 systems on a single Modbus serial link for up to 7936/3968 channels.

Redundant field lines for communication/supply.

Modbus interface RTU protocol on redundant RS-485.

RS-232 port for system configuration.

Three port isolation, Input/Output/Supply.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

Configurable by SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

Repeat Hazardous Area/Hazardous Locations input contact or proximity detector in Safe Area/Non Hazardous Locations via D2052M unit (relay output) or via D2053M unit (transistor output).


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Kí nìdí Yan Wa:

1. O le gba ohun elo pipe gẹgẹbi ibeere rẹ ni iye owo ti o kere julọ.

2. A tun pese Awọn atunṣe, FOB, CFR, CIF, ati ẹnu-ọna si awọn owo ifijiṣẹ ẹnu-ọna. A daba pe ki o ṣe adehun fun gbigbe eyiti yoo jẹ ọrọ-aje pupọ.

3. Awọn ohun elo ti a pese jẹ iṣeduro patapata, lati ọtun lati ijẹrisi idanwo ohun elo aise si alaye iwọn ipari. (Awọn ijabọ yoo ṣafihan lori ibeere)

4. A ṣe iṣeduro lati fun esi laarin awọn wakati 24 (nigbagbogbo ni wakati kanna)

5. O le gba awọn yiyan ọja iṣura, awọn ifijiṣẹ ọlọ pẹlu idinku akoko iṣelọpọ.

6. A ti wa ni kikun igbẹhin si awọn onibara wa. Ti ko ba ṣee ṣe lati pade awọn ibeere rẹ lẹhin idanwo gbogbo awọn aṣayan, a kii yoo tan ọ jẹ nipa ṣiṣe awọn ileri eke eyiti yoo ṣẹda awọn ibatan alabara to dara.


Kini yoo ṣẹlẹ nigbamii?

1. Imeeli ìmúdájú

Iwọ yoo gba imeeli ti o jẹrisi pe a ti gba ibeere rẹ.

2. Iyasoto Sales Manager

Ọkan ninu ẹgbẹ wa yoo wa ni ifọwọkan lati jẹrisi apakan (awọn) sipesifikesonu ati ipo.

3. Rẹ ń

Iwọ yoo gba agbasọ okeerẹ ti a ṣe deede si awọn iwulo pato rẹ.


2000+ Awọn ọja Wa gan

100% Brand New Factory edidi - Original

Sowo kaakiri agbaye - Awọn alabaṣiṣẹpọ Logistic UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Atilẹyin ọja Awọn oṣu 12 - Gbogbo awọn ẹya tuntun tabi tunpo

Ko si eto imulo ipadabọ wahala - Ẹgbẹ atilẹyin alabara igbẹhin

Isanwo - PayPal, Kirẹditi/kaadi debiti, tabi Gbigbe Bank/Waya

Payment


HKXYTECH kii ṣe olupin ti a fun ni aṣẹ tabi aṣoju ti awọn aṣelọpọ ti o ṣe ifihan lori oju opo wẹẹbu yii. Awọn orukọ iyasọtọ ati awọn aami-išowo ti a ṣe afihan jẹ ohun-ini ti awọn oniwun wọn.

Awọn ọja ti o ni ibatan
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Wiwa ọja