DESCRIPTION

The Digital Output Driver X1-IS-DO-01 module is suitable for energizing safety related circuits, up to SIL 3 level, for high risk industries. It can drive solenoid valves, visual or audible alarms to alert a plant operator, or other process control devices in Hazardous Area from control signals located in Safe Area. They can also be used as switchable supplies to power measuring or process control equipments. On the field side, the three most widespread Intrinsic Safety valve family parameters are supported. On the system side, a wide compatibility towards different DCS/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents spurious activations and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES

SIL 3 / SC 3

Input from Zone 0 / Division 1

Installation in Zone 2 / Division 2

Loop disconnection to ease maintenance operations

Short-circuit proof

Three different IS valve family parameters supported

Compatible with DCS/PLC pulse testing

Selectable input impedance (software programmable)

Three port isolation, Input/Output/Supply


CHANNELS

1


RELATED MODEL

D1046Y

D5040D

D5040S

D5048S

D5049S

D5240T

X1-IS-DO-01-S

X1-IS-DO-02-S

D1040Q

D1041Q

D1042Q

D1043Q

D1044D

D1044S

D1045Y

D1048S

D1049S

D5244D

D5244S

D1035S



Kutheni Ukhetha Thina:

1. Unokufumana izinto ezigqibeleleyo ngokwemfuno yakho ngexabiso elincinci elinokwenzeka.

2. Sikwabonelela ngeeReworks, FOB, CFR, CIF, kunye namaxabiso okuhanjiswa kweminyango. Sicebisa ukuba wenze isivumelwano sokuthumela ngenqanawe okuya kuba nokonga kakhulu.

3. Izinto esizibonelelayo zingqinisiseka ngokupheleleyo, ukusuka kwisatifikethi sovavanyo lwemathiriyeli ekrwada ukuya kwisiteyitimenti somgangatho wokugqibela.(Iingxelo ziya kubonisa ngokwemfuneko)

4. Siqinisekisa ukunika impendulo kwiiyure ezingama-24(ngokuqhelekileyo ngeyure enye)

5. Unokufumana ezinye iindlela zesitokhwe, ukuhanjiswa kwelitye kunye nokunciphisa ixesha lokuvelisa.

6. Sizinikezele ngokupheleleyo kubathengi bethu. Ukuba akunakwenzeka ukuhlangabezana neemfuno zakho emva kokuvavanya zonke iinketho, asiyi kukukhohlisa ngokwenza izithembiso zobuxoki eziza kudala ubudlelwane obuhle kubathengi.


Kwenzeka ntoni emva koko?

1. Ukuqinisekiswa kwe-imeyile

Uya kufumana i-imeyile eqinisekisa ukuba siwufumene umbuzo wakho.

2. UMphathi weNtengiso oKhethekileyo

Elinye leqela lethu liya kunxibelelana ukuze liqinisekise i(i)zahlulo zakho kunye nemeko.

3. Ucaphulo lwakho

Uya kufumana ikowuti ebanzi elungiselelwe iimfuno zakho ezithile.


Iimveliso ze-2000+ ezifumaneka ngokwenene

100% Umzi-mveliso omtsha otywiniweyo-Owokuqala

Ukuthumela ngeNqanaba kwiHlabathi liphela-Amaqabane oLungiselelo UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express...

Warranty 12 Months - Onke amalungu amatsha okanye reconditioned

Akukho mgaqo-nkqubo wembuyekezo wobunzima - Iqela elizinikeleyo lokuxhasa abathengi

Intlawulo-iPayPal, iTredit/debit card, okanye iBhanki/Udluliselo ngocingo

Payment


I-HKXYTECH ayingomthengisi ogunyazisiweyo okanye ummeli wabavelisi ababoniswe kule webhusayithi. Amagama eebhrendi kunye neempawu zokuthengisa ezibonakalisiweyo ziyipropathi yabanini bazo.

Iimveliso ezinxulumene noko
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators

Ukukhankatha kwemveliso