GMI X1-IS-DO-01-S I.S. SIL3 Digital Output Driver Intrinsically Safe Isolators

GMI
X1-IS-DO-01-S
Intrinsically Safe Isolators
Fast Delivery
GMI X1-IS-DO-01-S I.S. SIL3 Digital Output Driver Intrinsically Safe Isolators
Biz bilen habarlaşyň

Your email address will not be published. Required fields are marked with *

beýany

DESCRIPTION

The Digital Output Driver X1-IS-DO-01 module is suitable for energizing safety related circuits, up to SIL 3 level, for high risk industries. It can drive solenoid valves, visual or audible alarms to alert a plant operator, or other process control devices in Hazardous Area from control signals located in Safe Area. They can also be used as switchable supplies to power measuring or process control equipments. On the field side, the three most widespread Intrinsic Safety valve family parameters are supported. On the system side, a wide compatibility towards different DCS/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents spurious activations and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES

SIL 3 / SC 3

Input from Zone 0 / Division 1

Installation in Zone 2 / Division 2

Loop disconnection to ease maintenance operations

Short-circuit proof

Three different IS valve family parameters supported

Compatible with DCS/PLC pulse testing

Selectable input impedance (software programmable)

Three port isolation, Input/Output/Supply


CHANNELS

1


RELATED MODEL

D1046Y

D5040D

D5040S

D5048S

D5049S

D5240T

X1-IS-DO-01-S

X1-IS-DO-02-S

D1040Q

D1041Q

D1042Q

D1043Q

D1044D

D1044S

D1045Y

D1048S

D1049S

D5244D

D5244S

D1035S



Näme üçin bizi saýlaň:

1. Iň az bahadan talaplaryňyza görä ajaýyp material alyp bilersiňiz.

2. Şeýle hem, Reworks, FOB, CFR, CIF we gapydan gapylara eltiş bahalaryny hödürleýäris. Shük daşamak üçin gaty tygşytly iş etmegi maslahat berýäris.

3. Biziň berýän materiallarymyz, çig mal synag şahadatnamasyndan iň soňky ölçeg beýanyna çenli doly barlanýar. (Hasabatlar talap boýunça görkeziler)

4. 24 sagadyň dowamynda jogap bermegi kepillendirýäris (köplenç şol bir sagatda)

5. Önümçilik wagtyny azaltmak bilen aksiýa alternatiwalaryny, degirmen önümlerini alyp bilersiňiz.

6. Müşderilerimize doly wepaly. Optionshli wariantlary gözden geçireniňizden soň talaplaryňyza laýyk gelmeýän bolsa, gowy müşderi gatnaşyklaryny döredjek ýalan wadalar berip sizi ýalňyşmarys.


Ondan soň näme bolýar?

1. E-poçta tassyklamasy

Gözlegiňizi alandygymyzy tassyklaýan e-poçta alarsyňyz.

2. Aýratyn satuw dolandyryjysy

Toparymyzdan biri, bölümleriňizi (spesifikasiýaňyzy) we ýagdaýyňyzy tassyklamak üçin habarlaşar.

3. Sitata

Aýratyn zerurlyklaryňyza laýyk gelýän giňişleýin sitata alarsyňyz.


2000+ Önümler hakykatdanam bar

100% marka täze zawod möhürlenendir - asyl

Bütin dünýäde eltip bermek - Logistik hyzmatdaşlar UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Kepillik 12 aý - partshli bölekler täze ýa-da şertli

Hiç hili kynçylyk yzyna gaýtarmak syýasaty - Müşderi goldaw topary

Töleg - PayPal, kredit / debet kartoçkasy ýa-da bank / sim geçirişi

Payment


HKXYTECH ygtyýarly paýlaýjy ýa-da bu web sahypasynda görkezilen öndürijileriň wekili däl. Marka atlary we söwda bellikleri degişli eýeleriniň eýeçiligi.

Degişli önümler
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators

Önüm Gözlemek