GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

GMI
D2030M
Interface Multiplexer Systems
Fast Delivery
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
ITEANYE LE RONA

Your email address will not be published. Required fields are marked with *

Tlhaloso

DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Inputs from voltage free contacts or EN60947-5-6 proximity detectors from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Expandability up to 128 digital channels per system and 31 systems on a single Modbus serial link for up to 3968 channels.

Redundant field lines for communication/supply.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

High density, 32 channels per unit, 128 channels per system.

Configurable via D2050M Gateway using PC SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

1 terminal block per input, no external terminal block required.


CHANNELS

32


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Ke Hobane'ng ha U Re Khetha:

1. U ka fumana boitsebiso bo phethahetseng ho ea ka tlhokahalo ea hau bonyane theko e ka khonehang.

2. Re boetse re fana ka Reworks, FOB, CFR, CIF, le litheko tsa ho fana ka ntlo le ntlo. Re fana ka tlhahiso ea hore u etse tumellano ea ho tsamaisa thepa e tla u baballa haholo.

3. Thepa eo re fanang ka eona e ka netefatsoa ka botlalo, ho tloha ho setifikeiti sa tlhahlobo ea thepa e tala ho isa polelong ea ho qetela.(Litlaleho li tla hlaha ho latela tlhoko)

4. Re netefatsa ho fana ka karabo nakong ea lihora tse 24 (hangata ka hora e tšoanang)

5. U ka fumana mefuta e meng ea li-stock, ho tsamaisoa ha leloala ka ho fokotsa nako ea tlhahiso.

6. Re inehetse ka ho feletseng ho bareki ba rona. Haeba ho ke ke ha khoneha ho finyella litlhoko tsa hau ka mor'a ho hlahloba likhetho tsohle, re ke ke ra u khelosa ka ho etsa litšepiso tsa bohata tse tla theha likamano tse ntle tsa bareki.


Ho etsahala'ng ka mor'a moo?

1. Netefatso ea lengolo-tsoibila

U tla fumana lengolo-tsoibila le netefatsang hore re fumane potso ea hau.

2. Mookameli oa Thekiso e Ikhethang

E mong oa sehlopha sa rona o tla ikopanya le rona ho netefatsa lintlha le maemo a hau.

3. Khopolo ea hau

U tla fumana qotsulo e felletseng e ipapisitseng le litlhoko tsa hau tse ikhethileng.


Lihlahisoa tsa 2000+ Li fumaneha Hantle

100% Feme e Ncha e Tiisitsoeng - Ea mantlha

Thomello ea Lefatše ka Bophara - Balekane ba thepa UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Warranty 12 Months - Likarolo tsohle li ncha kapa li entsoe bocha

Ha ho leano la ho khutlisa mathata - Sehlopha se inehetseng sa tšehetso ea bareki

Tefo - PayPal, karete ea mokitlane/debit, kapa Bank/Wire Transfer

Payment


HKXYTECH ha se morekisi ea lumelletsoeng kapa moemeli oa bahlahisi ba hlahang webosaeteng ena. Mabitso a marang-rang le matšoao a hlahang ke thepa ea beng ba tsona ka ho fapana.

Lihlahisoa tse amanang
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Search Search