D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe Associated Apparatus for installation in Safe Area/Non Hazardous Locations to supply Multiplexer D2010M, D2011M, D2030M installed in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Universal inputs (mV, TC, RTD, contact or proximity detector) via D2010M, D2011M, D2030M unit from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Expandability up to 256 analog/128 digital channels per system and 31 systems on a single Modbus serial link for up to 7936/3968 channels.

Redundant field lines for communication/supply.

Modbus interface RTU protocol on redundant RS-485.

RS-232 port for system configuration.

Three port isolation, Input/Output/Supply.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

Configurable by SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

Repeat Hazardous Area/Hazardous Locations input contact or proximity detector in Safe Area/Non Hazardous Locations via D2052M unit (relay output) or via D2053M unit (transistor output).


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Aisea e Filifili ai Matou:

1. E mafai ona e mauaina le mea sili ona lelei e tusa ai ma lou manaʻoga i le tau maualalo.

2. Matou te ofoina atu foʻi Reworks, FOB, CFR, CIF, ma tau tuʻuina atu i le faitotoa. Matou te fautuaina oe e fai fefaʻatauaiga mo felauaiga o le a fai si taugofie.

3. O mea matou te tuʻuina atu e mafai ona faʻamaonia atoatoa, saʻo mai le tusi faʻataʻitaʻiga suʻega mataʻutia i le faʻamatalaga pito mulimuli.

4. Matou te faʻamautinoa e tuʻuina atu se tali i totonu ole 24 itula (masani i le itula lava e tasi)

5. E mafai ona e maua isi fa'atauga, fa'atauga fa'atauga ma fa'aitiitia le taimi o gaosiga.

6. Matou te faʻamaoni atoatoa ia matou tagata faʻatau. Afai o le a le mafai ona ausia ou manaʻoga pe a uma ona suʻesuʻeina filifiliga uma, matou te le faʻasesēina oe e ala i le faia o folafolaga pepelo e faʻatupuina sootaga lelei tagata faʻatau.


O le a le mea e sosoo ai?

1. Fa'amaumauga imeli

O le ae mauaina se imeli e faʻamaonia ai ua matou mauaina lau suʻesuʻega.

2. Pule Fa'atau Fa'atau

O se tasi o la matou 'au o le a faʻafesoʻotaʻi e faʻamaonia lau vaega (s) faʻamatalaga ma tulaga.

3. Lau upusii

O le ae mauaina se upusii atoatoa e fetaui ma ou manaoga faapitoa.


2000+ Oloa e Maua Moni

100% Fa'amaufa'ailoga Falegaosi Fou - Original

Va'a i le Lalolagi Atoa - Pa'aga fa'atauga UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express...

Fa'amaonia 12 Masina - O vaega uma e fou pe toe fa'aleleia

Leai se fa'alavelave toe fa'afo'i faiga fa'avae - 'Au'aunaga lagolago fa'apitoa

Totogi - PayPal, Credit/debit card, po'o Faletupe/Uea Fa'aliliu

Payment


HKXYTECH e le o se tufatufa faʻatagaina poʻo se sui o le au gaosi oloa o loʻo faʻaalia i luga o lenei upega tafaʻilagi. O igoa fa'ailoga ma fa'ailoga fa'ailoga o lo'o fa'aalia o meatotino a latou tagata e ona.

Fesootai oloa
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Oloa Saili