GMI X1-IS-UNI-01-S I.S. SIL3/2 Universal Module Intrinsically Safe Isolators

GMI
X1-IS-UNI-01-S
Intrinsically Safe Isolators
Fast Delivery
GMI X1-IS-UNI-01-S I.S. SIL3/2 Universal Module Intrinsically Safe Isolators
Twandikire

Your email address will not be published. Required fields are marked with *

ibisobanuro

DESCRIPTION

The Universal X1-IS-UNI-01 module is a high integrity interface suitable for applications requiring SIL 3 or SIL 2 level (depending on applications) in safety related systems for high risk industries. Thanks to its high flexibility, it can interface 2-wire active/passive 4-20 mA (AI), smart positioners (AO), switches and proximity detectors (DI), as well as solenoid valves and other process control devices (DO) located in Hazardous Area. HART® communication is supported for both active and passive transmitters, and I/P. The module always sinks current and the Termination Board extends its use to source loops. Programmable line and load open/short circuit detection and out-of-range current fault is also provided. The module automatically matches the application, without reprogramming; if required, it can be re-calibrated through the configuration software. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES

SIL 3/2 depending on applications / SC 3

Input from Zone 0 / Division 1

Installation in Zone 2 / Division 2

Loop disconnection to ease maintenance operations

Suitable for AI, AO, DI and DO applications without configuration

HART® compatible (passive and active AI/AO loops)

Line & Load short/open circuit programmable diagnostics

Out-of-range fault with programmable thresholds

Digital calibration available through configuration software

Input and Output short circuit proof

Field fault mirroring to the DCS/PLC UNI Card

High Accuracy

Three port isolation, Input/Output/Supply


CHANNELS

1


RELATED MODEL

X1-IS-UNI-01-S




Kuki Duhitamo:

1. Urashobora kubona ibikoresho byuzuye ukurikije ibyo usabwa byibuze kubiciro bishoboka.

2. Dutanga kandi Reworks, FOB, CFR, CIF, n'inzu kubiciro byo gutanga inzugi. Turagusaba gukora amasezerano yo kohereza bizaba byubukungu.

3. Ibikoresho dutanga birashobora kugenzurwa rwose, uhereye ku cyemezo cyibizamini fatizo kugeza ku ndunduro yanyuma. (Raporo izerekana kubisabwa)

4. Turemeza ko tuzatanga igisubizo mugihe cyamasaha 24 (mubisanzwe mumasaha imwe)

5. Urashobora kubona ubundi buryo bwimigabane, kugemura urusyo hamwe no kugabanya igihe cyo gukora.

6. Twiyeguriye byimazeyo abakiriya bacu. Niba bidashoboka kuzuza ibyo usabwa nyuma yo gusuzuma amahitamo yose, ntituzakuyobya dusezerana ibinyoma bizana umubano mwiza wabakiriya.


Bizagenda bite nyuma?

1. Kwemeza imeri

Uzabona imeri yemeza ko twakiriye iperereza ryawe.

2. Umuyobozi ushinzwe kugurisha bidasanzwe

Umwe mu itsinda ryacu azahuza kugirango yemeze igice cyawe.

3. Amagambo yawe

Uzakira amagambo yuzuye ajyanye nibyo ukeneye byihariye.


2000+ Ibicuruzwa Biraboneka Mubyukuri

100% Ikirangantego gishya gifunze - Umwimerere

Kohereza ku isi hose - Abafatanyabikorwa ba UPS / FedEx / DHL / EMS / SF Express / TNT / Express Deppon Express…

Garanti Amezi 12 - Ibice byose bishya cyangwa byasubiwemo

Nta kibazo cyo gusubiza politiki - Itsinda ryihariye ryunganira abakiriya

Kwishura - PayPal, Ikarita y'inguzanyo / ikarita yo kubikuza, cyangwa Banki / Ihererekanyabubasha

Payment


HKXYTECH ntabwo ari umugabuzi wemewe cyangwa uhagarariye ibicuruzwa bigaragara kururu rubuga. Amazina n'ibirango bigaragara ni umutungo wa ba nyirabyo.

Ibicuruzwa bijyanye
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators

Gushakisha ibicuruzwa