Pepperl+Fuchs KFD2-SH-Ex1.T.OP Switch Amplifiers Isolated Barriers

In stock
KFD2-SH-Ex1.T.OP
Pepperl+Fuchs
Switch Amplifiers
The KFD2-SH-Ex1.T.OP is a highly reliable 1-channel isolated barrier designed for intrinsic safety applications in industrial environments.
CONTACT US

Your email address will not be published. Required fields are marked with *

description

Pepperl+Fuchs KFD2-SH-Ex1.T.OP Switch Amplifiers Isolated Barriers


Description

The KFD2-SH-Ex1.T.OP is a highly reliable 1-channel isolated barrier designed for intrinsic safety applications in industrial environments. It enables the secure transfer of digital signals from NAMUR sensors or mechanical contacts in hazardous areas to safe areas. This model is powered by a 24 V DC supply and is equipped with form A normally open relay contacts for the safe area load. The device is constructed with a polycarbonate housing, ensuring durability and resistance to environmental stresses. Its protection degree of IP20 makes it suitable for indoor use in controlled environments. The KFD2-SH-Ex1.T.OP is designed to be mounted on a 35 mm DIN rail, adhering to EN 60715 standards, which simplifies installation and integration into existing infrastructure.


Features

The KFD2-SH-Ex1.T.OP features a removable terminal block with an integrated self-opening device, simplifying installation and wiring processes. The device operates within a temperature range of -20°C to 60°C, making it suitable for diverse environmental conditions. With a rated voltage of 20 to 30 V DC and a power consumption of < 1.3 W, the KFD2-SH-Ex1.T.OP ensures energy efficiency. Its compact design allows for efficient use of space, making it ideal for applications where panel space is limited. The device also supports line fault detection, which can be enabled or disabled via switch S3, enhancing operational safety and reliability. Additionally, it includes a unique collective error messaging feature when used with the Power Rail system, providing immediate notification of errors and enhancing system reliability. The switching point of the device is designed to operate within a range of 1.2 to 2.1 mA, with a switching hysteresis of approximately 0.2 mA, ensuring precise and reliable signal transmission. The device also supports a pulse/pause ratio of ≥ 20 ms/≥ 20 ms, making it suitable for applications requiring precise timing and control.


Function

The primary function of the KFD2-SH-Ex1.T.OP is to transfer digital signals from hazardous areas to safe areas while maintaining galvanic isolation between the two. This ensures that any noise, potential differences, or transients from the hazardous area do not affect the safe area control circuits. The device uses a zener barrier in combination with a galvanic isolation network to limit the energy transmitted to the field, thereby ensuring intrinsic safety. In the event of a fault in the field circuit, the relays revert to their de-energized state, and the LEDs on the device indicate the fault according to NAMUR NE44 standards. This feature ensures quick identification and resolution of issues, minimizing downtime. The KFD2-SH-Ex1.T.OP is certified for use in hazardous locations, adhering to international safety standards and protocols, making it suitable for applications in oil and gas refineries, chemical plants, and other hazardous environments where safety and reliability are paramount.


KCD2-SR-Ex1.LB

KFD2-SR2-Ex1.W

KFA5-SR2-Ex1.W

KFA6-SR2-Ex1.W

KFD2-SR2-Ex1.W.LB

KFA5-SR2-Ex1.W.LB

KFA6-SR2-Ex1.W.LB

KCD2-SR-Ex2

KFD2-SR2-Ex2.W

KFA5-SR2-Ex2.W

KFA6-SR2-Ex2.W

KFA5-SR2-Ex2.W.IR

KFA6-SR2-Ex2.W.IR

KFD2-SR2-Ex2.2S

KFD2-SRA-Ex4

KFD2-SR-Ex1.4S.LK

KFD2-ST2-Ex1.LB

KFD2-ST2-Ex2

KFD2-SOT2-Ex1.LB

KFD2-SOT2-Ex1.LB.IO

KFD2-SOT2-Ex1.N

KFD2-SOT2-Ex2

KFA5-SOT2-Ex2

KFA6-SOT2-Ex2

KFD2-SOT2-Ex2.IO

KFD2-SH-Ex1

KFD2-SH-Ex1.T.OP

KHA6-SH-Ex1

KFD2-DU-Ex1.D

KFA5-DU-Ex1.D

KFA6-DU-Ex1.D



Why Choose Us:

1. You can get the perfect material according to your requirement at the least possible price.

2. We also offer Reworks, FOB, CFR, CIF, and door to door delivery prices. We suggest you to do deal for shipping which will be quite economical.

3. The materials we provide are completely verifiable, right from raw material test certificate to the final dimensional statement.(Reports will show on requirement)

4. We guarantee to give a response within 24hours(usually in the same hour)

5. You can get stock alternatives, mill deliveries with minimizing manufacturing time.

6. We are fully dedicated to our customers. If it will not possible to meet your requirements after examining all options, we will not mislead you by making false promises which will create good customer relations.


What happens next?

1. Email confirmation

You will get an email confirming that we have received your enquiry.

2. Exclusive Sales Manager

One of our team will be in touch to confirm your part(s) specification and condition.

3. Your quote

You will receive a comprehensive quote tailored to your specific needs.


2000+ Products Really Available

100% Brand New Factory Sealed - Original

Worldwide Shipping - Logistic partners UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Warranty 12 Months - All parts new or reconditioned

No hassle returns policy - Dedicated customer support team

Payment - PayPal, Credit/debit card, or Bank/Wire Transfer

Payment


HKXYTECH is not an authorized distributor or representative of the manufacturers featured on this website. Brand names and trademarks featured are the property of their respective owners.

RELATED PRODUCTS
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
The device limits induced transients of different causes, e. g. lightning or switching operations. The limitation is achieved by diverting the current to earth and limiting the signal loop voltage during the duration of the overvoltage pulse.
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 18 ..

Product search