Pepperl+Fuchs KCD2-STC-EX1 1-channel SMART Transmitter Power Supply

In stock
KCD2-STC-EX1
Pepperl+Fuchs
Transmitter Power Supply
1-channel isolated barrier 24 V DC supply (Power Rail) Input for 2-wire SMART transmitters and current sources Output for 4 mA ... 20 mA or 1 V ... 5 V Housing width 12.5 mm Up to SIL 2 (SC 3) acc. to IEC/EN 61508
CONTACT US

Your email address will not be published. Required fields are marked with *

description

Pepperl+Fuchs KCD2-STC-EX1 1-channel SMART Transmitter Power Supply


Feature

1-channel isolated barrier

24 V DC supply (Power Rail)

Input for 2-wire SMART transmitters and current sources

Output for 4 mA ... 20 mA or 1 V ... 5 V

Housing width 12.5 mm

Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Pepperl+Fuchs KCD2-STC-EX1 1-channel SMART Transmitter Power Supply


Function

This isolated barrier is used for intrinsic safety applications.

The device supplies 2-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.

It transfers the analog input signal to the safe area as an isolated current value.

Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.

Selectable output of current source, sink mode, or voltage output is available via DIP switches.

If the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 6 and 8 can be used.

Test sockets for the connection of HART communicators are integrated into the terminals of the device.

Pepperl+Fuchs KCD2-STC-EX1 1-channel SMART Transmitter Power Supply

Pepperl+Fuchs KCD2 STC EX1 1-channel SMART Transmitter Power Supply

Pepperl+Fuchs KCD2STCEX1 1-channel SMART Transmitter Power Supply


Why Choose Us:

1. You can get the perfect material according to your requirement at the least possible price.

2. We also offer Reworks, FOB, CFR, CIF, and door to door delivery prices. We suggest you to do deal for shipping which will be quite economical.

3. The materials we provide are completely verifiable, right from raw material test certificate to the final dimensional statement.(Reports will show on requirement)

4. We guarantee to give a response within 24hours(usually in the same hour)

5. You can get stock alternatives, mill deliveries with minimizing manufacturing time.

6. We are fully dedicated to our customers. If it will not possible to meet your requirements after examining all options, we will not mislead you by making false promises which will create good customer relations.


What happens next?

1. Email confirmation

You will get an email confirming that we have received your enquiry.

2. Exclusive Sales Manager

One of our team will be in touch to confirm your part(s) specification and condition.

3. Your quote

You will receive a comprehensive quote tailored to your specific needs.


2000+ Products Really Available

100% Brand New Factory Sealed - Original

Worldwide Shipping - Logistic partners UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Warranty 12 Months - All parts new or reconditioned

No hassle returns policy - Dedicated customer support team

Payment - PayPal, Credit/debit card, or Bank/Wire Transfer

Payment


HKXYTECH is not an authorized distributor or representative of the manufacturers featured on this website. Brand names and trademarks featured are the property of their respective owners.

RELATED PRODUCTS
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
The device limits induced transients of different causes, e. g. lightning or switching operations. The limitation is achieved by diverting the current to earth and limiting the signal loop voltage during the duration of the overvoltage pulse.
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 18 ..

Product search