Pepperl+Fuchs KCD2-SR-Ex2 2-channel Switch Amplifier

In stock
KCD2-SR-Ex2
Pepperl+Fuchs
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2
CONTACT US

Your email address will not be published. Required fields are marked with *

description

Pepperl+Fuchs KCD2-SR-Ex2 2-channel Switch Amplifier 


Description

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2

Pepperl+Fuchs KCD2-SR-Ex2 2-channel Switch Amplifier 


Function

This isolated barrier is used for intrinsic safety applications.

The device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.

The proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when the input signal changes the state.

Via switches the mode of operation can be reversed and the line fault detection can be switched off.

During a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.

If the device is operated via Power Rail, additionally a collective error message is available.

Due to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in space-critical applications.

Pepperl+Fuchs KCD2-SR-Ex2 2-channel Switch Amplifier 

Pepperl+Fuchs KCD2 SR Ex2 2-channel Switch Amplifier 

Pepperl+Fuchs KCD2SREx2 2-channel Switch Amplifier 


Why Choose Us:

1. You can get the perfect material according to your requirement at the least possible price.

2. We also offer Reworks, FOB, CFR, CIF, and door to door delivery prices. We suggest you to do deal for shipping which will be quite economical.

3. The materials we provide are completely verifiable, right from raw material test certificate to the final dimensional statement.(Reports will show on requirement)

4. We guarantee to give a response within 24hours(usually in the same hour)

5. You can get stock alternatives, mill deliveries with minimizing manufacturing time.

6. We are fully dedicated to our customers. If it will not possible to meet your requirements after examining all options, we will not mislead you by making false promises which will create good customer relations.


What happens next?

1. Email confirmation

You will get an email confirming that we have received your enquiry.

2. Exclusive Sales Manager

One of our team will be in touch to confirm your part(s) specification and condition.

3. Your quote

You will receive a comprehensive quote tailored to your specific needs.


2000+ Products Really Available

100% Brand New Factory Sealed - Original

Worldwide Shipping - Logistic partners UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Warranty 12 Months - All parts new or reconditioned

No hassle returns policy - Dedicated customer support team

Payment - PayPal, Credit/debit card, or Bank/Wire Transfer

Payment


HKXYTECH is not an authorized distributor or representative of the manufacturers featured on this website. Brand names and trademarks featured are the property of their respective owners.

RELATED PRODUCTS
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
Pepperl+Fuchs K-LB-1.30G 1-Channel Surge Protection Barrier
The device limits induced transients of different causes, e. g. lightning or switching operations. The limitation is achieved by diverting the current to earth and limiting the signal loop voltage during the duration of the overvoltage pulse.
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
Pepperl+Fuchs KFD2-SR2-EX2.W 2-channel Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
Pepperl+Fuchs K-LB-2.30G 2-channel Surge Protection Barrier
2-channel, Mounting on DIN mounting rail, For intrinsically safe or non-intrinsically safe 30 V applications, Protects field or control circuit inputs, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 4, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
Pepperl+Fuchs KFD2-STC5-1 1-channel Transmitter Power Supply
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 18 ..

Product search