DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Inputs from voltage free contacts or EN60947-5-6 proximity detectors from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Expandability up to 128 digital channels per system and 31 systems on a single Modbus serial link for up to 3968 channels.

Redundant field lines for communication/supply.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

High density, 32 channels per unit, 128 channels per system.

Configurable via D2050M Gateway using PC SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

1 terminal block per input, no external terminal block required.


CHANNELS

32


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Għaliex Agħżilna:

1. Tista 'tikseb il-materjal perfett skond il-ħtieġa tiegħek bl-inqas prezz possibbli.

2. Noffru wkoll Reworks, FOB, CFR, CIF, u prezzijiet tal-kunsinna bieb bieb. Nissuġġerixxu li tagħmel ftehim għat-tbaħħir li se jkun pjuttost ekonomiku.

3. Il-materjali li nipprovdu huma kompletament verifikabbli, sa minn ċertifikat tat-test tal-materja prima sad-dikjarazzjoni dimensjonali finali. (Ir-rapporti se juru fuq il-ħtieġa)

4. Aħna niggarantixxu li nagħtu tweġiba fi żmien 24 siegħa (ġeneralment fl-istess siegħa)

5. Tista 'tikseb alternattivi ta' stokk, kunsinni tal-mitħna b'minimizzazzjoni tal-ħin tal-manifattura.

6. Aħna ddedikati bis-sħiħ lill-klijenti tagħna. Jekk ma jkunx possibbli li tissodisfa r-rekwiżiti tiegħek wara li neżaminaw l-għażliet kollha, aħna mhux se nqarrquk billi nagħmlu wegħdiet foloz li joħolqu relazzjonijiet tajba mal-klijenti.


X'jiġri wara?

1. Email konferma

Se tirċievi email li tikkonferma li rċevejna l-mistoqsija tiegħek.

2. Manager tal-Bejgħ Esklussiva

Wieħed mit-tim tagħna se jagħmel kuntatt biex jikkonferma l-ispeċifikazzjoni u l-kundizzjoni tal-parti(jiet) tiegħek.

3. Il-kwotazzjoni tiegħek

Inti ser tirċievi kwotazzjoni komprensiva mfassla għall-bżonnijiet speċifiċi tiegħek.


2000+ Prodotti Verament Disponibbli

100% Brand New Factory Issiġillat - Oriġinali

Shipping madwar id-dinja - Imsieħba loġistika UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express...

Garanzija 12-il Xahar - Il-partijiet kollha ġodda jew rikondizzjonati

Ebda politika ta 'ritorni battikata - Tim dedikat għall-appoġġ tal-klijenti

Ħlas - PayPal, karta ta 'kreditu/debitu, jew Trasferiment tal-Bank/Wire

Payment


HKXYTECH mhuwiex distributur awtorizzat jew rappreżentant tal-manifatturi li jidhru fuq din il-websajt. L-ismijiet tad-ditta u t-trademarks li jidhru huma l-proprjetà tas-sidien rispettivi tagħhom.

Prodotti relatati
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Tfittxija tal-prodott