GMI X1-IS-AO-01-S I.S. SIL3 HART Isolating Driver Intrinsically Safe Isolators

GMI
X1-IS-AO-01-S
Intrinsically Safe Isolators
Fast Delivery
GMI X1-IS-AO-01-S I.S. SIL3 HART Isolating Driver Intrinsically Safe Isolators
KONTAKTÉIERT EIS

Your email address will not be published. Required fields are marked with *

Broessdatsch

DESCRIPTION

The Isolating Driver X1-IS-AO-01 module is a high integrity analog output interface suitable for applications requiring SIL 3 level in safety related systems for high risk industries. It isolates and transfers a 4-20 mA signal from a controller located in Safe Area to a load in Hazardous Area. The circuit allows bi-directional communication signals, for HART® smart positioners. Line and load open/short circuit detection is provided: the fault in the field is directly mirrored to the PLC AO card as open circuit and it is also reported on the common fault line. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES

SIL 3 / SC 3

Input from Zone 0 / Division 1

Installation in Zone 2 / Division 2

Loop disconnection to ease maintenance operations

HART® compatible

Line & Load short/open circuit programmable diagnostics

Out-of-range fault with programmable thresholds

Field fault mirroring to the DCS/PLC IO Card

High Accuracy

Three port isolation, Input/Output/Supply


CHANNELS

1


RELATED MODEL

D1022D

D1022S

D5020D

D5020S

X1-IS-AO-01-S

X1-IS-AO-02-S

D1020D

D1020S



Firwat eis wielen:

1. Dir kënnt de perfekte Material no Äre Bedierfnesser zum mannst méigleche Präis kréien.

2. Mir bidden och Reworks, FOB, CFR, CIF, an Dier zu Dier Liwwerung Präisser. Mir proposéieren Iech eng Deal fir Versand ze maachen, wat zimmlech ekonomesch wäert sinn.

3. D'Materialien, déi mir ubidden, si komplett verifizéierbar, direkt vum Rohmaterial Test Zertifikat bis zur Finale Dimensiounserklärung. (Rapporte wäerten op Ufuerderung weisen)

4. Mir garantéieren eng Äntwert bannent 24 Stonnen ze ginn (normalerweis an der selwechter Stonn)

5. Dir kënnt Stock Alternativen kréien, Millen Liwwerungen mat minimiséieren Fabrikatioun Zäit.

6. Mir sinn voll un eise Clienten éige. Wann et net méiglech ass Är Ufuerderungen ze erfëllen nodeems Dir all Optiounen ënnersicht hutt, wäerte mir Iech net täuschen andeems Dir falsch Verspriechen mécht, déi gutt Clientsbezéiungen kreéieren.


Wat geschitt dann?

1. Email Confirmatiouns

Dir kritt eng E-Mail déi confirméiert datt mir Är Ufro kritt hunn.

2. Exklusiv Sales Manager

Ee vun eisem Team wäert a Kontakt sinn fir Är Deel(en) Spezifizéierung an Zoustand ze bestätegen.

3. Ären Zitat

Dir kritt eng ëmfaassend Devis op Är spezifesch Besoinen ugepasst.


2000+ Produkter wierklech verfügbar

100% Brand New Factory Sealed - Original

Weltwäit Versand - Logistesch Partner UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Garantie 12 Méint - All Deeler nei oder renovéiert

Keng Problemer Retour Politik - Engagéiert Client Ënnerstëtzung Equipe

Bezuelen - PayPal, Kreditt / Bankkaart, oder Bank / Iwwerweisung

Payment


HKXYTECH ass keen autoriséierten Distributeur oder Vertrieder vun den Hiersteller op dëser Websäit. Markennamen a Marken déi ugewise sinn sinn d'Besëtz vun hire jeeweilege Besëtzer.

Betrëfft
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators

Propronal Sich