GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System

GMI
D2010M
Interface Multiplexer Systems
Fast Delivery
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
KONTAKTÉIERT EIS

Your email address will not be published. Required fields are marked with *

Broessdatsch

DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2010M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2010M scans all channels using state of the art solid state isolated relays, and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2010M unit accepts directly up to 16 input channels and, by adding from one to three D2011M units, is expandable to 64 channels in blocks of 16 channels each. Four D2010M units, connected to twelve D2011M Expander units, achieve 256 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. An integrating type, high rejection, high accuracy (18 bits) A/D converter, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.


FEATURES

Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.

Expandability up to 256 analog channels per system and 31 systems on a single Modbus serial link for up to 7936 channels.

Redundant field lines for communication/supply.

High accuracy A/D converter, 18 bits.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

High density, 16 channels per unit, 256 channels per system.

Configurable via D2050M Gateway using PC SWC2090 software (free of charge) or user software.

Modbus output allows savings on PLC/DCS I/O cards cost.

Lower cables, installation and maintenance costs.

1 terminal block per input, no external terminal block required.


CHANNELS

16


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Firwat eis wielen:

1. Dir kënnt de perfekte Material no Äre Bedierfnesser zum mannst méigleche Präis kréien.

2. Mir bidden och Reworks, FOB, CFR, CIF, an Dier zu Dier Liwwerung Präisser. Mir proposéieren Iech eng Deal fir Versand ze maachen, wat zimmlech ekonomesch wäert sinn.

3. D'Materialien, déi mir ubidden, si komplett verifizéierbar, direkt vum Rohmaterial Test Zertifikat bis zur Finale Dimensiounserklärung. (Rapporte wäerten op Ufuerderung weisen)

4. Mir garantéieren eng Äntwert bannent 24 Stonnen ze ginn (normalerweis an der selwechter Stonn)

5. Dir kënnt Stock Alternativen kréien, Millen Liwwerungen mat minimiséieren Fabrikatioun Zäit.

6. Mir sinn voll un eise Clienten éige. Wann et net méiglech ass Är Ufuerderungen ze erfëllen nodeems Dir all Optiounen ënnersicht hutt, wäerte mir Iech net täuschen andeems Dir falsch Verspriechen mécht, déi gutt Clientsbezéiungen kreéieren.


Wat geschitt dann?

1. Email Confirmatiouns

Dir kritt eng E-Mail déi confirméiert datt mir Är Ufro kritt hunn.

2. Exklusiv Sales Manager

Ee vun eisem Team wäert a Kontakt sinn fir Är Deel(en) Spezifizéierung an Zoustand ze bestätegen.

3. Ären Zitat

Dir kritt eng ëmfaassend Devis op Är spezifesch Besoinen ugepasst.


2000+ Produkter wierklech verfügbar

100% Brand New Factory Sealed - Original

Weltwäit Versand - Logistesch Partner UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Garantie 12 Méint - All Deeler nei oder renovéiert

Keng Problemer Retour Politik - Engagéiert Client Ënnerstëtzung Equipe

Bezuelen - PayPal, Kreditt / Bankkaart, oder Bank / Iwwerweisung

Payment


HKXYTECH ass keen autoriséierten Distributeur oder Vertrieder vun den Hiersteller op dëser Websäit. Markennamen a Marken déi ugewise sinn sinn d'Besëtz vun hire jeeweilege Besëtzer.

Betrëfft
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2011M Intrinsically Safe Analog-Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Propronal Sich