GMI X1-IS-UNI-01-S I.S. SIL3/2 Universal Module Intrinsically Safe Isolators

GMI
X1-IS-UNI-01-S
Intrinsically Safe Isolators
Fast Delivery
GMI X1-IS-UNI-01-S I.S. SIL3/2 Universal Module Intrinsically Safe Isolators
Kontakte nou

Your email address will not be published. Required fields are marked with *

deskripsyon

DESCRIPTION

The Universal X1-IS-UNI-01 module is a high integrity interface suitable for applications requiring SIL 3 or SIL 2 level (depending on applications) in safety related systems for high risk industries. Thanks to its high flexibility, it can interface 2-wire active/passive 4-20 mA (AI), smart positioners (AO), switches and proximity detectors (DI), as well as solenoid valves and other process control devices (DO) located in Hazardous Area. HART® communication is supported for both active and passive transmitters, and I/P. The module always sinks current and the Termination Board extends its use to source loops. Programmable line and load open/short circuit detection and out-of-range current fault is also provided. The module automatically matches the application, without reprogramming; if required, it can be re-calibrated through the configuration software. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES

SIL 3/2 depending on applications / SC 3

Input from Zone 0 / Division 1

Installation in Zone 2 / Division 2

Loop disconnection to ease maintenance operations

Suitable for AI, AO, DI and DO applications without configuration

HART® compatible (passive and active AI/AO loops)

Line & Load short/open circuit programmable diagnostics

Out-of-range fault with programmable thresholds

Digital calibration available through configuration software

Input and Output short circuit proof

Field fault mirroring to the DCS/PLC UNI Card

High Accuracy

Three port isolation, Input/Output/Supply


CHANNELS

1


RELATED MODEL

X1-IS-UNI-01-S




Poukisa chwazi nou:

1. Ou ka jwenn materyèl la pafè dapre egzijans ou nan pri a pi piti posib.

2. Nou ofri tou Reworks, FOB, CFR, CIF, ak pri livrezon pòt an pòt. Nou sijere ou fè kontra pou anbake ki pral byen ekonomik.

3. Materyèl nou bay yo konplètman verifye, dwa soti nan sètifika tès materyèl anvan tout koreksyon nan deklarasyon dimansyon final la. (Rapò yo pral montre sou kondisyon)

4. Nou garanti bay yon repons nan lespas 24 èdtan (anjeneral nan menm èdtan an)

5. Ou ka jwenn altènativ stock, livrezon moulen ak minimize tan fabrikasyon.

6. Nou konplètman dedye a kliyan nou yo. Si li pa pral posib satisfè kondisyon ou apre yo fin egzamine tout opsyon, nou pa pral twonpe ou lè nou fè fo pwomès ki pral kreye bon relasyon kliyan.


Kisa k ap pase apre?

1. Imèl konfimasyon

Ou pral resevwa yon imèl ki konfime ke nou te resevwa demann ou an.

2. Manadjè Komèsyal Eksklizif

Youn nan ekip nou an pral kontakte pou konfime spesifikasyon pati ou a ak kondisyon.

3. site ou

Ou pral resevwa yon sitasyon konplè ki adapte a bezwen espesifik ou yo.


2000+ pwodwi vrèman disponib

100% mak nouvo faktori sele - orijinal

Shipping atravè lemond - Patnè lojistik UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express ...

Garanti 12 Mwa - Tout pati nouvo oswa rkondisyone

Pa gen okenn pwoblèm retounen politik - Ekip sipò kliyan dedye

Peman - PayPal, kat kredi/debi, oswa transfè labank/fil

Payment


HKXYTECH se pa yon distribitè otorize oswa reprezantan manifaktirè yo prezante sou sit entènèt sa a. Non mak ak mak ki prezante yo se pwopriyete pwopriyetè respektif yo.

Pwodwi ki gen rapò
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011D I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5011S I.S. SIL3 2-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5014D I.S. SIL3 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators
GMI D5015SK I.S. SIL2 2/4-Wire HART Transmitter Power Supply Intrinsically Safe Isolators

Pwodwi rechèch