Your email address will not be published. Required fields are marked with *
DESCRIPTION
D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer Expander D2011M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2011M scans all channels using state of the art solid state isolated relays, and stores all data in the D2010M memory buffer connected to it, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2011M unit accepts directly up to 16 input channels. An integrating type, high rejection, high accuracy (18 bits) A/D converter installed on D2010M unit that control up to three Expander D2011M, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit and stored in the D2010M unit connected to the Expander.
FEATURES
Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.
Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.
Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.
EMC Compatibility to EN61000-6-2, EN61000-6-4.
High reliability, SMD components.
High density, 16 channels per unit.
1 terminal block per input, no external terminal block required.
CHANNELS
16
RELATED MODELS
D2010M
D2011M
D2030M
D2050M
D2052M
D2053M
Poukisa chwazi nou:
1. Ou ka jwenn materyèl la pafè dapre egzijans ou nan pri a pi piti posib.
2. Nou ofri tou Reworks, FOB, CFR, CIF, ak pri livrezon pòt an pòt. Nou sijere ou fè kontra pou anbake ki pral byen ekonomik.
3. Materyèl nou bay yo konplètman verifye, dwa soti nan sètifika tès materyèl anvan tout koreksyon nan deklarasyon dimansyon final la. (Rapò yo pral montre sou kondisyon)
4. Nou garanti bay yon repons nan lespas 24 èdtan (anjeneral nan menm èdtan an)
5. Ou ka jwenn altènativ stock, livrezon moulen ak minimize tan fabrikasyon.
6. Nou konplètman dedye a kliyan nou yo. Si li pa pral posib satisfè kondisyon ou apre yo fin egzamine tout opsyon, nou pa pral twonpe ou lè nou fè fo pwomès ki pral kreye bon relasyon kliyan.
Kisa k ap pase apre?
1. Imèl konfimasyon
Ou pral resevwa yon imèl ki konfime ke nou te resevwa demann ou an.
2. Manadjè Komèsyal Eksklizif
Youn nan ekip nou an pral kontakte pou konfime spesifikasyon pati ou a ak kondisyon.
3. site ou
Ou pral resevwa yon sitasyon konplè ki adapte a bezwen espesifik ou yo.
2000+ pwodwi vrèman disponib
100% mak nouvo faktori sele - orijinal
Shipping atravè lemond - Patnè lojistik UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express ...
Garanti 12 Mwa - Tout pati nouvo oswa rkondisyone
Pa gen okenn pwoblèm retounen politik - Ekip sipò kliyan dedye
Peman - PayPal, kat kredi/debi, oswa transfè labank/fil

HKXYTECH se pa yon distribitè otorize oswa reprezantan manifaktirè yo prezante sou sit entènèt sa a. Non mak ak mak ki prezante yo se pwopriyete pwopriyetè respektif yo.
Pwodwi rechèch