DESCRIPTION

D2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single/redundant 2 wires data communication/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer Expander D2011M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2011M scans all channels using state of the art solid state isolated relays, and stores all data in the D2010M memory buffer connected to it, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2011M unit accepts directly up to 16 input channels. An integrating type, high rejection, high accuracy (18 bits) A/D converter installed on D2010M unit that control up to three Expander D2011M, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit and stored in the D2010M unit connected to the Expander.


FEATURES

Intrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area/Hazardous Location.

Universal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.

Isolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.

EMC Compatibility to EN61000-6-2, EN61000-6-4.

High reliability, SMD components.

High density, 16 channels per unit.

1 terminal block per input, no external terminal block required.


CHANNELS

16


RELATED MODELS

D2010M

D2011M

D2030M

D2050M

D2052M

D2053M



Carson a thaghas sinn sinn:

1. Gheibh thu an stuth foirfe a rèir do riatanas aig a 'phrìs as lugha a tha comasach.

2. Bidh sinn cuideachd a 'tairgse Reworks, FOB, CFR, CIF, agus prìsean lìbhrigidh doras gu doras. Tha sinn a’ moladh dhut cùmhnant a dhèanamh airson luingearachd a bhios gu math eaconamach.

3. Tha na stuthan a bheir sinn seachad gu tur dearbhach, dìreach bho theisteanas deuchainn stuthan amh chun an aithris mu dheireadh meud.

4. Tha sinn a 'gealltainn freagairt a thoirt seachad taobh a-staigh 24 uairean (mar as trice anns an aon uair)

5. Gheibh thu roghainnean stoc eile, lìbhrigeadh muilne le bhith a 'lùghdachadh ùine saothrachaidh.

6. Tha sinn gu tur coisrigte don luchd-ceannach againn. Mura h-urrainn dhuinn na riatanasan agad a choileanadh às deidh sgrùdadh a dhèanamh air a h-uile roghainn, cha bhith sinn gad mhealladh le bhith a’ dèanamh gheallaidhean meallta a chruthaicheas deagh dhàimhean teachdaiche.


Dè thachras a-nis?

1. Dearbhadh post-d

Gheibh thu post-d a dhearbhas gu bheil sinn air do cheist fhaighinn.

2. Manaidsear Reic Sònraichte

Bidh aon den sgioba againn ann an conaltradh gus dearbhadh a dhèanamh air do chuid (ean) sònrachadh agus suidheachadh.

3. Do chuis

Gheibh thu cuòt coileanta a rèir na feumalachdan sònraichte agad.


2000+ toradh ri fhaighinn dha-rìribh

100% Factaraidh Ùr snasail air a seuladh - tùsail

Luingearachd air feadh an t-saoghail - Com-pàirtichean loidsistigs UPS / FedEx / DHL / EMS / SF Express / TNT / Deppon Express…

Barantas 12 mìosan - A h-uile pàirt ùr no ath-nuadhachadh

Poileasaidh tilleadh gun duilgheadas - Sgioba taic teachdaiche sònraichte

Pàigheadh ​​- PayPal, cairt creideas/fiach, no gluasad banca/uèir

Payment


Chan eil HKXYTECH na neach-cuairteachaidh ùghdarraichte no riochdaire an luchd-saothrachaidh a tha a’ nochdadh air an làrach-lìn seo. Is ann leis na sealbhadairean aca a tha na h-ainmean branda agus na comharran-malairt a tha rim faicinn.

Toraidhean co-cheangailte
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI 5700-110 SIL3 HART Mux Modem for Termination Board HART Modem Interface Multiplexer Systems
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2010M Intrinsically Safe Analog-Temperature Multiplexer Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System
GMI D2030M Intrinsically Safe Digital Multiplexer DIN-Rail Model Intrinsically Safe Multiplexer System

Rannsachadh toraidh